Ваш браузер устарел. Рекомендуем обновить его до последней версии.

The Flash-Recorder-2 MITX self-recording voltmeter is a small-sized data collection system running under the Windows Embedded standard 7 operating system and is an industrial version of the Flash-Recorder-2-16/. It has the same technical characteristics, differs in the built-in processor to make the final turnkey solution according to buyer’s technical task.

The presence of a built-in processor allows you to create stands and automated systems based on it with information output to an external display connected linked to the HDMI connector.

Technical specification:

Characteristic

Meaning

DC voltage measure range (bipolar)

From – 10 up to + 10

Limits of the permissible basic reduced accuracy of measuring DC voltage, %*

± 0,1

(option  ±0,05)

Measuring range of the RMS value of the AC voltage, V

From 0 up to 10

Limits of the permissible basic reduced error of measuring the RMS value of the AC voltage, %*

± 0,1

(option  ±0,05)

Frequency of AC voltage, Hz

From 0 up to 3000

DC power measuring range  , мА

From 0 up to 5

From 4 up to 20

Limits of the permissible basic reduced error of measuring DC power, %*

± 1

(option  ±0,5)

Measuring range of time intervals, ms

От 10 до 10000

Limits of the permissible basic relative error of measuring time intervals, %

± 1 (option  ±0,5)

Input overload, V 

 not more, than ± 40

Number of analog inputs

(differential/multiplexed, with common wire)

Flash-Recorder-2-16-MITX1

 

 

8/16

Number of digital input/output channels

8/8 

Number of synchronic ADC channels

2

ADC resolution

16

Maximum frequency of ADC conversion per channel, kHz

5

Gain factors of the programmable amplifier

1, 10, 100, 200

Input impedance, MOm, not less, than

1

Bandwidth by minus level 3 dB, kHz, not less, than

3

Insulation resistance between input and case, МОм, not less, than

1

DC power supply voltage, V

12

Communication interface with an external PC

Ethernet

Maximum distance from the computer to the devices, m

500

Overall dimensions (length×width×height), mm

160×150×50

Weight not more, than, kg

3

Normal conditions of use:

– temperature, °С

– humidity, %

– air pressure, kPa

 

20 ± 5

up to 85

from 84,0 up to 106,7

Working conditions :

temperature, °С

 

 

humidity, %

air pressure, kPa

 

from + 5 up to + 50

(option

from – 25 up to + 70)

up to 90

from 84,0 up to 106,7

Average time to failure, h, at least

10000

Average service life, years, at least

7